Our company puts emphasis on the management, the introduction of talented personnel, and the construction of staff building, trying hard to improve the quality and liability consciousness of staff members. Our company successfully attained IS9001 Certification and European CE Certification of
Ac Thermostat That Works With Alexa
,
Hvac Condensate Float Switch
,
Electronically Actuated Valves
, We warmly welcome you to build cooperation and generate a brilliant long term together with us.
Well-designed Ball Valve Solenoid Actuator -
S6061-32D Standard Damper Actuator (Non Fail-Safe Damper Actuators) – Soloon Detail:
Features of S6061-32D Standard Damper Actuator (Non Fail-Safe Damper Actuators)
- Torque 32NM
- 2 or 3 points
- Actuator and damper shaft are bolt-on by screw.
- Maximum round shaft φ20 and square shaft 16*16mm.
- Direction of rotation can be setting.
- Manuel Override
- With 2 auxiliary switches are optional
- Power supply AC/DC 24V or AC 230V
Outline and Mounting Dimension of S6061-32D Standard Damper Actuator (Non Fail-Safe Damper Actuators)
Technical Datasheet of S6061-32D Standard Damper Actuator (Non Fail-Safe Damper Actuators)
| Item |
Unit |
S6061-32DN(F)
|
S6061-32DN(F)
|
| Torque |
Nm |
32 Nm |
| Damper area |
m2 |
6 m2 |
| Running time |
sec |
114~138 |
| Power supply |
V |
24VAC/DC |
220VAC |
| Frequency |
Hz |
50/60
7.5W 50/60Hz |
| Running consumption |
W |
4.0W |
5.5W |
| Maintaining consumption |
W |
0.5W |
1.0W |
| Weight |
Kg |
1.25Kg |
| Control signal |
2/3 point |
| Rotation angle |
0~90º(Max 93°) |
| Limited angle |
5~85º(Per step 5º) |
| Auxiliary switch rating |
3(1.5)Amp 250V |
| Life cycle |
>70000 cycles |
| Noise level |
45dB(A) |
| Electrical level |
Ⅱ |
| Protection level |
IP44 or IP54 |
| Ambient Temperature |
-20~+50℃ |
| Ambient Humidity |
5~95%RH |
| Storage temperature |
-40~+70℃ |
| Certificate |
CE UL(Except 230V) |
Remark: After lead to the actuator wire through PG joint, the protection level can reach IP54.
Wiring Diagram of S6061-32D Standard Damper Actuator (Non Fail-Safe Damper Actuators)

Wiring Diagram of S6061-32D Standard Damper Actuator (Non Fail-Safe Damper Actuators)

Resistance feedback
Auxiliary Switch of S6061-32D Standard Damper Actuator (Non Fail-Safe Damper Actuators)
There are two auxiliary switches of S6061-32DF damper actuator, can set the angle 0-90° (factory sets 10° and 80°), it will show a signal when the actuator turns to the setting angle.

Angle of Rotation Limiting of S6061-32D Standard Damper Actuator (Non Fail-Safe Damper Actuators)
The rotation angle or working range of the actuator can be adjusted 5°by adapter so that can limit mechanically. You just press the locking clip to lose the adapter.
Control Signal and Choose the Rotate Direction of S6061-32D Standard Damper Actuator (Non Fail-Safe Damper Actuators)
Must make the contact pin(C) in as Same direction as motor plug.

Factory setting:
Switch an at 10° Switch b at 80° The switching position can be manually changed to any required position by turning the ratchet.
What is HVAC Air Duct Damper Actuator?
The Function of HVAC Air Duct Damper Actuator
Product detail pictures:
Related Product Guide:
To constantly improve the management system by virtue of the rule of "sincerely, good faith and quality are the base of enterprise development", we widely absorb the essence of related products internationally, and constantly develop new products to meet the demands of customers for
Well-designed Ball Valve Solenoid Actuator -
S6061-32D Standard Damper Actuator (Non Fail-Safe Damper Actuators) – Soloon , The product will supply to all over the world, such as: Jersey
, Jordan
, Munich
, We adopt advanced production equipment and technology, and perfect testing equipment and methods to ensure our product quality. With our high-level talents, scientific management, excellent teams, and attentive service, our merchandise are favored by domestic and foreign customers. With your support, we'll build a better tomorrow!