We have many excellent staff members good at marketing, QC, and dealing with kinds of troublesome problem in the production process for
Ac Thermostat Temperature Sensor
,
Hvac Remote Sensor
,
Electrically Actuated Water Valve
, We warmly welcome small business companions from all walks of lifestyle, hope to establish friendly and cooperative business make contact with with you and attain a win-win objective.
Renewable Design for Remote Actuated Valve -
S6062A Control Valve Actuator – Soloon Detail:
Features of S6062A Control Valve Actuator
- Die-casting aluminum bracket and ABS cover
- Actuator can meet different pressure demand
- Synchronous motor, equip with shut power function, it can open at any position due to supply stable torque
- forward and reversal control setting meet different valve body
Installation and Cautions of S6062A Control Valve Actuator
1. Reserve enough space for maintenance during installation.
2. The wiring shall comply with the national electrical construction specification, and conducted in the case of power off.
3. The actuator should not be covered by thermal insulation material to prevent it from heat dissipation.
4. Vertical installation should be given priority, and inclined or horizontal installation can be adopted in special occasions, but support and fixation should be added when the volume, weight and vibration are too large.
5. Manual valves are recommended to be installed at both ends of the control valve to facilitate maintenance. During use, grease should be added regularly for three or four months.
6. When the installation position of the control valve is not indicated on the design drawing, the control valve is generally installed on the return water pipe.
Installation Diagram of S6062A Control Valve Actuator

1. Insert the actuator into valve stem

2. Tight two screws use hex key

3. Use manual lever to adjust the stroke, then put gasket into slot, last tight the nut
Attention: the assemble must vertical between actuator and valve body
Dimension of S6062A Control Valve Actuator

Manual Operation:
1. Insert handle
2. Rotate “UP” and “DOWN”.
Technical Parameter of S6062A Control Valve Actuator
| Item No. |
S6062A-DV |
S6062A-FV |
S6062A-MV |
| Voltage |
AC220±15% |
AC24V±15% |
AC24V±15% |
| Power |
16VA |
| Input Signal |
on off |
Floating |
0-10VDC/4-20mA |
| Feedback Signal |
——- |
—— |
0-10VDC/4-20mA |
| Act Speed(mm/s) |
0.20(50Hz) |
| Max. Stroke(mm) |
44mm |
| Output Force(N) |
2500/4000/5000 |
| End Connection |
Buckle |
| Height(mm) |
379 |
| Weight(kgs) |
4.7 |
Environment Temperature: -5℃~55℃ 2.Storage Temperature:-2℃~85℃ 3. Protect Class: IP 44

Modulating Wiring of S6062A Control Valve Actuator

The Manufacturer of HVAC Control Valves and Valve Actuators
The HVAC Actuator Valve Working Principle
HVAC Control Valves and Actuators
Product detail pictures:
Related Product Guide:
Our organization has been focusing on brand strategy. Customers' gratification is our greatest advertising. We also source OEM provider for
Renewable Design for Remote Actuated Valve -
S6062A Control Valve Actuator – Soloon , The product will supply to all over the world, such as: Victoria
, Kenya
, Madrid
, Our technical expertise, customer-friendly service, and specialized merchandise make us/company name the first choice of customers and vendors. We've been looking for your inquiry. Let's set up the cooperation right now!