Our company insists all along the quality policy of product quality is base of enterprise survival; customer satisfaction is the staring point and ending of an enterprise; persistent improvement is eternal pursuit of staff and the consistent purpose of reputation first, customer first for
Automated Globe Valve
,
Motorised Valve Types
,
Hvac Airflow Sensor
, We are going to do our greatest to satisfy or exceed customers' prerequisites with excellent goods, advanced concept, and economical and timely company. We welcome all clients.
Personlized Products Fan Coil Unit Valve -
S6062A Control Valve Actuator – Soloon Detail:
Features of S6062A Control Valve Actuator
- Die-casting aluminum bracket and ABS cover
- Actuator can meet different pressure demand
- Synchronous motor, equip with shut power function, it can open at any position due to supply stable torque
- forward and reversal control setting meet different valve body
Installation and Cautions of S6062A Control Valve Actuator
1. Reserve enough space for maintenance during installation.
2. The wiring shall comply with the national electrical construction specification, and conducted in the case of power off.
3. The actuator should not be covered by thermal insulation material to prevent it from heat dissipation.
4. Vertical installation should be given priority, and inclined or horizontal installation can be adopted in special occasions, but support and fixation should be added when the volume, weight and vibration are too large.
5. Manual valves are recommended to be installed at both ends of the control valve to facilitate maintenance. During use, grease should be added regularly for three or four months.
6. When the installation position of the control valve is not indicated on the design drawing, the control valve is generally installed on the return water pipe.
Installation Diagram of S6062A Control Valve Actuator

1. Insert the actuator into valve stem

2. Tight two screws use hex key

3. Use manual lever to adjust the stroke, then put gasket into slot, last tight the nut
Attention: the assemble must vertical between actuator and valve body
Dimension of S6062A Control Valve Actuator

Manual Operation:
1. Insert handle
2. Rotate “UP” and “DOWN”.
Technical Parameter of S6062A Control Valve Actuator
| Item No. |
S6062A-DV |
S6062A-FV |
S6062A-MV |
| Voltage |
AC220±15% |
AC24V±15% |
AC24V±15% |
| Power |
16VA |
| Input Signal |
on off |
Floating |
0-10VDC/4-20mA |
| Feedback Signal |
——- |
—— |
0-10VDC/4-20mA |
| Act Speed(mm/s) |
0.20(50Hz) |
| Max. Stroke(mm) |
44mm |
| Output Force(N) |
2500/4000/5000 |
| End Connection |
Buckle |
| Height(mm) |
379 |
| Weight(kgs) |
4.7 |
Environment Temperature: -5℃~55℃ 2.Storage Temperature:-2℃~85℃ 3. Protect Class: IP 44

Modulating Wiring of S6062A Control Valve Actuator

The Manufacturer of HVAC Control Valves and Valve Actuators
The HVAC Actuator Valve Working Principle
HVAC Control Valves and Actuators
Product detail pictures:
Related Product Guide:
We often stay with the principle Quality Very first, Prestige Supreme. We have been fully committed to supplying our consumers with competitively priced high-quality goods, prompt delivery and skilled provider for
Personlized Products Fan Coil Unit Valve -
S6062A Control Valve Actuator – Soloon , The product will supply to all over the world, such as: Auckland
, Pakistan
, Switzerland
, Adhering to the management tenet of Managing Sincerely, Winning by Quality, we try our best to provide excellent products and service to our clients. We look forward to making progress together with domestic and international clients.