Soloon Controls (Beijing) Co., Ltd. +86 10 67863711
soloon-logo
soloon-logo
Contact Us
S6025 Fluid Level Switch

Original Factory Fcu 2 Way Valve - S6062A Control Valve Actuator – Soloon

Original Factory Fcu 2 Way Valve -
 S6062A Control Valve Actuator  – Soloon
We have state-of-the-art tools. Our products are exported towards the USA, the UK and so on, enjoying a fantastic reputation amongst customers for Air Duct Temperature Sensor , Control Valve Actuator Types , 4 Way Motorized Mixing Valve , For further queries or should you have any question regarding our products, please do not hesitate to contact us.
Original Factory Fcu 2 Way Valve - S6062A Control Valve Actuator – Soloon Detail:

Features of S6062A Control Valve Actuator

  1. Die-casting aluminum bracket and ABS cover
  2. Actuator can meet different pressure demand
  3. Synchronous motor, equip with shut power function, it can open at any position due to supply stable torque
  4. forward and reversal control setting meet different valve body

Installation and Cautions of S6062A Control Valve Actuator

1. Reserve enough space for maintenance during installation.

2. The wiring shall comply with the national electrical construction specification, and conducted in the case of power off.

3. The actuator should not be covered by thermal insulation material to prevent it from heat dissipation.

4. Vertical installation should be given priority, and inclined or horizontal installation can be adopted in special occasions, but support and fixation should be added when the volume, weight and vibration are too large.

5. Manual valves are recommended to be installed at both ends of the control valve to facilitate maintenance. During use, grease should be added regularly for three or four months.

6. When the installation position of the control valve is not indicated on the design drawing, the control valve is generally installed on the return water pipe.

Installation Diagram of S6062A Control Valve Actuator

Installation_Diagram1

1. Insert the actuator into valve stem

Installation_Diagram2

2. Tight two screws use hex key

Installation_Diagram3

3. Use manual lever to adjust the stroke, then put gasket into slot, last tight the nut

Attention: the assemble must vertical between actuator and valve body

Dimension of S6062A Control Valve Actuator

Dimension-of-S6062A-Control-Valve-Actuator

Manual Operation:

1. Insert handle

2. Rotate “UP” and “DOWN”.

Technical Parameter of S6062A Control Valve Actuator

Item No. S6062A-DV S6062A-FV S6062A-MV
Voltage AC220±15% AC24V±15% AC24V±15%
Power 16VA
Input Signal on off Floating 0-10VDC/4-20mA
Feedback Signal ——- —— 0-10VDC/4-20mA
Act Speed(mm/s) 0.20(50Hz)
Max. Stroke(mm) 44mm
Output Force(N) 2500/4000/5000
End Connection Buckle
Height(mm) 379
Weight(kgs) 4.7

Environment Temperature: -5℃~55℃ 2.Storage Temperature:-2℃~85℃ 3. Protect Class: IP 44

S6062A-series-Actuator-Instruction

 

Modulating Wiring of S6062A Control Valve Actuator

Modulating-Wiring-of-S6062A-Control-Valve-Actuator

 

The Manufacturer of HVAC Control Valves and Valve Actuators

The HVAC Actuator Valve Working Principle

HVAC Control Valves and Actuators


Product detail pictures:

Original Factory Fcu 2 Way Valve -
 S6062A Control Valve Actuator  – Soloon detail pictures


Related Product Guide:

We are going to dedicate ourselves to providing our esteemed buyers together with the most enthusiastically thoughtful products and services for Original Factory Fcu 2 Way Valve - S6062A Control Valve Actuator – Soloon , The product will supply to all over the world, such as: Israel , South Africa , Plymouth , With excellent solutions, high quality service and sincere attitude of service, we ensure customer satisfaction and help customers create value for mutual benefit and create a win-win situation. Welcome customers all over the world to contact us or visit our company. We'll satisfy you with our qualified service!
Contact Us Product Inquiry
Contact Us
If you are interested in our products.
Please fill in the form & Contact Us.
+86 10 67863711