Manufactur standard Valve Actuator Controller -
S6061SF-10/15 Fire Smoke Damper Actuator – Soloon Detail:
Features of S6061SF-10-15 Fire Smoke Damper Actuator
- ON/OFF or 0-10V
- Shaft size up to 12* 12mm
- Two fixed auxiliary switches
- With IP54 standard
- Without Manuel Override
- 72℃ thermal sensor are optional
Technical Datasheet of S6061SF-10-15 Fire Smoke Damper Actuator
| Item |
S6061SF-10DF(S)/24V |
S6061SF-10DF(S)/230V |
S6061SF-10AF/24V |
S6061SF-15DF(S)/24V |
S6061SF-15DF(S)/230V |
S6061SF-15AF/24V |
| Torque |
10Nm |
15Nm |
| Damper area |
2m2 |
3m2 |
| Power supply |
24VAC/DC; 230VAC 50/60Hz, |
| Operating Power Consumption |
5W |
6W |
| At end stops Power Consumption |
2.5W |
2.5W |
| Wire size |
10VA |
7VA |
10VA |
7VA |
| Connection cable |
D type power:1m cable 2*0.75 m2 A type power:1m cable 4*0.5 m2 |
| Auxiliary switch (F):1m cable 6*0.5 m2 |
| Thermal sensor(S):1m cable 2*0.5 m2 |
| Control signal |
On/off |
0~10V |
On/off |
0~10V |
| Running time |
motor≤100S;spring return≤20S |
motor≤130S;spring return≤20S |
| Rotation angle |
0~90°(Max 93º) |
| Indicate |
Mechanical indicator |
| Weight |
2.6Kg |
| Life cycle |
70000 |
| Noise level |
50dB(A) and 62dB(A) |
| Electric level |
Ⅲ |
Ⅱ |
Ⅲ |
Ⅲ |
Ⅱ |
Ⅲ |
| IP protection |
IP54 |
| Ambient Temperature |
-20~+50℃ |
| Ambient Humidity |
5~95%RH |
| Standard |
CE & UL |
Diagram and Dimension of S6061SF-10-15 Fire Smoke Damper Actuator

Auxiliary Switch of S6061SF-10-15 Fire Smoke Damper Actuator

Dimension of S6061SF-10-15 Fire Smoke Damper Actuator

72℃ thermal sensor
Including: environment(TS1) and damper thermal sensor (TS2);
when the temperature over 72℃, TS1 will be cut;
when the pipe temperature over 72℃, TS2 will be cut.

What is HVAC Air Duct Damper Actuator?
The Function of HVAC Air Duct Damper Actuator
Product detail pictures:
Related Product Guide:
We have now probably the most innovative production equipment, experienced and qualified engineers and workers, regarded high quality control systems and also a friendly expert income team pre/after-sales support for
Manufactur standard Valve Actuator Controller -
S6061SF-10/15 Fire Smoke Damper Actuator – Soloon , The product will supply to all over the world, such as: Finland
, Spain
, Muscat
, Our products are mainly exported to Europe, Africa, America, the Middle East and Southeast Asia and other countries and regions. We have enjoyed a great reputation among our customers for quality products and good services.We would make friends with businessmen from at home and abroad, following the purpose of Quality First, Reputation First, the Best Services.