We depend on sturdy technical force and continually create sophisticated technologies to meet the demand of Motorized Heating Valve , Thermostatic Actuator , Hvac Pressure Transmitter , All the opinions and suggestions will be greatly appreciated! The good cooperation could improve both of us into better development!
Manufactur standard Co2 Sensor In Ahu – S6011-RT/RTH Series of Temperature Transmitter & Temperature-Humidity Transmitter – Soloon Detail:

Operation voltage DC 24V
Output signal 0~10V or 4-20mA
Measuring range Temperature 0~50℃
Humidity 0~100%RH
Measuring Accuracy Temperature ±1℃ or ±0.5℃
RH ±5%RH or ±3%
Ambient temperature -20℃~60℃
Storage -40℃~70℃, non-condensing
Housing ABS

Dimensions of S6011-RT/RTH Series of Temperature Transmitter & Temperature-humidity Transmitter

s6011-rt-rth-series-of-temperature-transmitter-temperature-humidity-transmitter-2

S6011-RT Wiring diagram of S6011-RT/RTH Series of Temperature Transmitter & Temperature-humidity Transmitter

s6011-rt-rth-series-of-temperature-transmitter-temperature-humidity-transmitter-3

S6011-RTH Wiring diagram of S6011-RT/RTH Series of Temperature Transmitter & Temperature-humidity Transmitter

s6011-rt-rth-series-of-temperature-transmitter-temperature-humidity-transmitter-4

Mounting of S6011-RT/RTH Series of Temperature Transmitter & Temperature-humidity Transmitter

  • The transmitters are suitable for direct wall mounting or ceiling mounting using four screw holes on the base. The wiring must be inserted from the back. For mounting:
  • Choose an appropriate location to achieve good control of the ambient temperature. The room transmitters only sense the temperature or humidity at the location where it is mounted.
  • The transmitters should not be mounted close to windows or doors in order to avoid draught. On the other hand, sufficient air circulation must be ensured in order to sense the actual temperature of the room.
  • Place insulation material in the wiring conduit in order to prevent the introduction of air from outside the room.
  • The transmitter should not be exposed to direct radiation or to the sun as this could lead to inaccurate measurement.

Product detail pictures:

Manufactur standard Co2 Sensor In Ahu – S6011-RT/RTH Series of Temperature Transmitter & Temperature-Humidity Transmitter   – Soloon detail pictures


Related Product Guide:

Control the standard by the details, show the toughness by quality. Our firm has strived to establish a highly efficient and stable workers workforce and explored an effective high-quality management system for Manufactur standard Co2 Sensor In Ahu – S6011-RT/RTH Series of Temperature Transmitter & Temperature-Humidity Transmitter – Soloon , The product will supply to all over the world, such as: Cape Town , Juventus , Canada , Satisfaction and good credit to every customer is our priority. We focus on every detail of order processing for customers till they have received safe and sound solutions with good logistics service and economical cost. Depending on this, our solutions are sold very well in the countries in Africa, the Mid-East and Southeast Asia.
Contact Us Product Inquiry
Contact Us
If you are interested in our products.
Please fill in the form & Contact Us.
+86 10 67863711