Our organization sticks to your principle of Quality may be the life of your organization, and reputation will be the soul of it for
50mm Electric Actuated Ball Valve
,
Actuator Globe Valve
,
3 Way Motorized Ball Valve
, Our final target is To consider the most effective, To be the Best. Please experience cost-free to call with us if you have any prerequisites.
High definition Zone Damper Actuator -
S6062A Control Valve Actuator – Soloon Detail:
Features of S6062A Control Valve Actuator
- Die-casting aluminum bracket and ABS cover
- Actuator can meet different pressure demand
- Synchronous motor, equip with shut power function, it can open at any position due to supply stable torque
- forward and reversal control setting meet different valve body
Installation and Cautions of S6062A Control Valve Actuator
1. Reserve enough space for maintenance during installation.
2. The wiring shall comply with the national electrical construction specification, and conducted in the case of power off.
3. The actuator should not be covered by thermal insulation material to prevent it from heat dissipation.
4. Vertical installation should be given priority, and inclined or horizontal installation can be adopted in special occasions, but support and fixation should be added when the volume, weight and vibration are too large.
5. Manual valves are recommended to be installed at both ends of the control valve to facilitate maintenance. During use, grease should be added regularly for three or four months.
6. When the installation position of the control valve is not indicated on the design drawing, the control valve is generally installed on the return water pipe.
Installation Diagram of S6062A Control Valve Actuator

1. Insert the actuator into valve stem

2. Tight two screws use hex key

3. Use manual lever to adjust the stroke, then put gasket into slot, last tight the nut
Attention: the assemble must vertical between actuator and valve body
Dimension of S6062A Control Valve Actuator

Manual Operation:
1. Insert handle
2. Rotate “UP” and “DOWN”.
Technical Parameter of S6062A Control Valve Actuator
| Item No. |
S6062A-DV |
S6062A-FV |
S6062A-MV |
| Voltage |
AC220±15% |
AC24V±15% |
AC24V±15% |
| Power |
16VA |
| Input Signal |
on off |
Floating |
0-10VDC/4-20mA |
| Feedback Signal |
——- |
—— |
0-10VDC/4-20mA |
| Act Speed(mm/s) |
0.20(50Hz) |
| Max. Stroke(mm) |
44mm |
| Output Force(N) |
2500/4000/5000 |
| End Connection |
Buckle |
| Height(mm) |
379 |
| Weight(kgs) |
4.7 |
Environment Temperature: -5℃~55℃ 2.Storage Temperature:-2℃~85℃ 3. Protect Class: IP 44

Modulating Wiring of S6062A Control Valve Actuator

The Manufacturer of HVAC Control Valves and Valve Actuators
The HVAC Actuator Valve Working Principle
HVAC Control Valves and Actuators
Product detail pictures:
Related Product Guide:
Our company sticks into the basic principle of Quality is definitely the life of the business, and status may be the soul of it for
High definition Zone Damper Actuator -
S6062A Control Valve Actuator – Soloon , The product will supply to all over the world, such as: Slovak Republic
, Nairobi
, Zambia
, We are trying our best to make more customers happy and satisfied. we sincerely hope to establish a good long-term business relationship with your esteemed company thought this opportunity,based on equal, mutual beneficial and win win business from now till the future.