S6025 Fluid Level Switch

High definition Air Flow Sensor For Hvac - S6022 Flow Switch – Soloon

High definition Air Flow Sensor For Hvac -
 S6022 Flow Switch  – Soloon
Our intention should be to fulfill our consumers by offering golden provider, superior price and superior quality for Normally Closed Motorized Ball Valve , Pvc Motorized Valve , Duct Damper Actuator , Therefore, we can meet different inquiries from different consumers. You should find our web page to check additional info from our products.
High definition Air Flow Sensor For Hvac - S6022 Flow Switch – Soloon Detail:

Feature of S6025 Fluid Level Switch

Rated voltage VRated Current A Power COS ø 125VAC 250V AC
No induced load current 1 15 15
Induced load Full load current 0.75 3.5 2.5
Current Instantaneous current 0.45 21 15

Figure1: Technological Parameter 1

Valve Size Connector MaxPressure

(Mpa)

Protection AllowableMedium Temp. Wet.(Kg) Modulating Range of Flow
Pipe Size Min. Max.
Flow decrease Flow increase Flow decrease Flow increase
3″ 1″-11½ (NPT) 1.60 IP65 -30~120 0.6 1″ 2.5 4.2 8.5 8.8
2″ 9.5 13.7 27 29
3″ 19 27.5 50 53

Figure 2: Technological Parameter 2

When there is sufficient fluid through the pipe, the loop closes up between red and blue contacts.

s6022-flow-switch-2

Mounting of S6022 Flow Switch

  • Mount the switch in a section of pipe where there is a straight run of at least five pipe diameters on each side of the flow switch.
  • The switch should be mounted so that the terminals or wire leads are easily accessible for wiring.
  • Screw the flow switch into position so that the flat of the paddle is at a right angle to the flow. The arrow on the side of the case must point in the direction of the flow.
  • The switch must be mounted in a horizontal pipeline or a vertical pipeline with upward liquid flow. It is not recommended for installation where liquid flow is downwards. When mounted in a vertical pipe with the upward flow the switch trips will operate at a slightly higher flow than shown in Figure 4: “Typical Flow Rates”, due to the effect of gravity on the switch mechanism.
  • All wiring connections must be made using copper conductors only.
  • All wiring must be installed in accordance with the National Electric Code and local regulations

Flow Rate of S6022 Flow Switch

 

* + GPM figures are for a switch with a 6” paddle.

* For 4” and 5” line pipes, the 6” paddle is trimmed to a 4” and 5” length, respectively.

* For switching action, refer to figure 3.

GPM (m3/hr) Required to Actuate Switch
Pipe Size (in.) 1 1-1/4 1-1/2 2 2-1/2 3 4* 5* 6* 8*
Minimum Adjustment Flow increasingred→yellow

closed**

4.2(1.0) 5.8(1.3) 7.5(1.7) 13.7(3.1) 18.0(4.1) 27.5(6.2) 65.0(14.8)

37.0+

(8.4)

125.0(28.4)

57.0+

(12.9)

190.0(43.1)

74.0+

(16.8)

375.0(85.2)

205.0+

(46.6)

Flow decreasingred→blue

closed**

2.5(0.6) 3.7(0.8) 5.0(1.1) 9.5(2.2) 12.5(2.8) 19.0(4.3) 50.0(11.4)

27.0+

(6.1)

101.0(22.9)

41.0+

(9.3)

158.0(35.9)

54.0+

(12.3)

320.0(72.7)

170.0+

(38.6)

Maximum Adjustment Flow increasingred→yellow

closed**

8.8(2.0) 13.3(3.0) 19.2(4.4) 29.0(6.6) 34.5(7.8) 53.0(12.0) 128.0(29.1)

81.0+

(18.4)

245.0(55.6)

118.0+

(26.8)

375.0(85.2)

144.0

(32.7)

760.0(172.6)

415.0+

(94.2)

Flow decreasingred→blue

closed**

8.5(1.9) 12.5(2.8) 18.0(4.1) 27.0(6.1) 32.0(7.3) 50.0(11.4) 122.0(27.7)

76.0+

(17.3)

235(53.4)

111.0+

(25.2)

360.0(81.8)

135.0+

(30.7)

730.0(165.8)

400.0+

(90.8)


Product detail pictures:

High definition Air Flow Sensor For Hvac -
 S6022 Flow Switch  – Soloon detail pictures


Related Product Guide:

Having a positive and progressive attitude to customer's fascination, our organization constantly improves our solution high-quality to fulfill the requirements of shoppers and further focuses on safety, reliability, environmental prerequisites, and innovation of High definition Air Flow Sensor For Hvac - S6022 Flow Switch – Soloon , The product will supply to all over the world, such as: Manchester , Stuttgart , India , We set a strict quality control system. We have return and exchange policy, and you can exchange within 7 days after receive the wigs if it is in new station and we service repairing free for our products. Please feel free to contact us for further information if you have any questions. We are glad to work for every client.
Contact Us Product Inquiry
Contact Us
If you are interested in our products.
Please fill in the form & Contact Us.
+86 10 67863711