We take pleasure in a really excellent name amongst our shoppers for our exceptional product or service excellent, competitive rate and also the greatest services for
Hvac Thermocouple
,
Motorized Control Ball Valve
,
Zoned Hvac Thermostat
, Our firm warmly welcome friends from everywhere in the globe to visit, examine and negotiate business enterprise.
Super Purchasing for Electric 3 Way Valve -
S6062A Control Valve Actuator – Soloon Detail:
Features of S6062A Control Valve Actuator
- Die-casting aluminum bracket and ABS cover
- Actuator can meet different pressure demand
- Synchronous motor, equip with shut power function, it can open at any position due to supply stable torque
- forward and reversal control setting meet different valve body
Installation and Cautions of S6062A Control Valve Actuator
1. Reserve enough space for maintenance during installation.
2. The wiring shall comply with the national electrical construction specification, and conducted in the case of power off.
3. The actuator should not be covered by thermal insulation material to prevent it from heat dissipation.
4. Vertical installation should be given priority, and inclined or horizontal installation can be adopted in special occasions, but support and fixation should be added when the volume, weight and vibration are too large.
5. Manual valves are recommended to be installed at both ends of the control valve to facilitate maintenance. During use, grease should be added regularly for three or four months.
6. When the installation position of the control valve is not indicated on the design drawing, the control valve is generally installed on the return water pipe.
Installation Diagram of S6062A Control Valve Actuator

1. Insert the actuator into valve stem

2. Tight two screws use hex key

3. Use manual lever to adjust the stroke, then put gasket into slot, last tight the nut
Attention: the assemble must vertical between actuator and valve body
Dimension of S6062A Control Valve Actuator

Manual Operation:
1. Insert handle
2. Rotate “UP” and “DOWN”.
Technical Parameter of S6062A Control Valve Actuator
| Item No. |
S6062A-DV |
S6062A-FV |
S6062A-MV |
| Voltage |
AC220±15% |
AC24V±15% |
AC24V±15% |
| Power |
16VA |
| Input Signal |
on off |
Floating |
0-10VDC/4-20mA |
| Feedback Signal |
——- |
—— |
0-10VDC/4-20mA |
| Act Speed(mm/s) |
0.20(50Hz) |
| Max. Stroke(mm) |
44mm |
| Output Force(N) |
2500/4000/5000 |
| End Connection |
Buckle |
| Height(mm) |
379 |
| Weight(kgs) |
4.7 |
Environment Temperature: -5℃~55℃ 2.Storage Temperature:-2℃~85℃ 3. Protect Class: IP 44

Modulating Wiring of S6062A Control Valve Actuator

The Manufacturer of HVAC Control Valves and Valve Actuators
HVAC Control Valves and Actuators
Product detail pictures:
Related Product Guide:
Often customer-oriented, and it's our ultimate target to become not only probably the most reputable, trustable and honest provider, but also the partner for our customers for
Super Purchasing for Electric 3 Way Valve -
S6062A Control Valve Actuator – Soloon , The product will supply to all over the world, such as: Ghana
, Sudan
, Sweden
, Meanwhile, we're building up and consummating triangle market & strategic cooperation in order to achieve a multi-win trade supply chain to expand our market vertically and horizontally for a brighter prospects. development. Our philosophy is to create cost-effective products and solutions, promote perfect services, cooperate for long-term and mutual benefits, firm a in depth mode of excellent suppliers system and marketing agents, brand strategic cooperation sales system.