Rapid Delivery for Ball Valve Motorized -
S6062A Control Valve Actuator – Soloon Detail:
Features of S6062A Control Valve Actuator
- Die-casting aluminum bracket and ABS cover
- Actuator can meet different pressure demand
- Synchronous motor, equip with shut power function, it can open at any position due to supply stable torque
- forward and reversal control setting meet different valve body
Installation and Cautions of S6062A Control Valve Actuator
1. Reserve enough space for maintenance during installation.
2. The wiring shall comply with the national electrical construction specification, and conducted in the case of power off.
3. The actuator should not be covered by thermal insulation material to prevent it from heat dissipation.
4. Vertical installation should be given priority, and inclined or horizontal installation can be adopted in special occasions, but support and fixation should be added when the volume, weight and vibration are too large.
5. Manual valves are recommended to be installed at both ends of the control valve to facilitate maintenance. During use, grease should be added regularly for three or four months.
6. When the installation position of the control valve is not indicated on the design drawing, the control valve is generally installed on the return water pipe.
Installation Diagram of S6062A Control Valve Actuator

1. Insert the actuator into valve stem

2. Tight two screws use hex key

3. Use manual lever to adjust the stroke, then put gasket into slot, last tight the nut
Attention: the assemble must vertical between actuator and valve body
Dimension of S6062A Control Valve Actuator

Manual Operation:
1. Insert handle
2. Rotate “UP” and “DOWN”.
Technical Parameter of S6062A Control Valve Actuator
| Item No. |
S6062A-DV |
S6062A-FV |
S6062A-MV |
| Voltage |
AC220±15% |
AC24V±15% |
AC24V±15% |
| Power |
16VA |
| Input Signal |
on off |
Floating |
0-10VDC/4-20mA |
| Feedback Signal |
——- |
—— |
0-10VDC/4-20mA |
| Act Speed(mm/s) |
0.20(50Hz) |
| Max. Stroke(mm) |
44mm |
| Output Force(N) |
2500/4000/5000 |
| End Connection |
Buckle |
| Height(mm) |
379 |
| Weight(kgs) |
4.7 |
Environment Temperature: -5℃~55℃ 2.Storage Temperature:-2℃~85℃ 3. Protect Class: IP 44

Modulating Wiring of S6062A Control Valve Actuator

The Manufacturer of HVAC Control Valves and Valve Actuators
The HVAC Actuator Valve Working Principle
HVAC Control Valves and Actuators
Product detail pictures:
Related Product Guide:
We support our prospective buyers with ideal top quality merchandise and superior level provider. Becoming the specialist manufacturer in this sector, we have now attained abundant practical expertise in producing and managing for
Rapid Delivery for Ball Valve Motorized -
S6062A Control Valve Actuator – Soloon , The product will supply to all over the world, such as: Romania
, Vietnam
, Luxemburg
, We believe that good business relationships will lead to mutual benefits and improvement for both parties. We now have established long-term and successful cooperative relationships with many customers through their confidence in our customized services and integrity in doing business. We also enjoy a high reputation through our good performance. Better performance will be expected as our principle of integrity. Devotion and Steadiness will remain as ever.