PriceList for Outside Air Damper Actuator -
S6061-08-16-24 Standard Damper Actuator (Non Fail-Safe Damper Actuators) – Soloon Detail:
Features of S6061-08~24 Standard Damper Actuator (Non Fail-Safe Damper Actuators)
- Torque 08-16-24NM
- 2 or 3 points control or Modulating
- Actuator and damper shaft are bolt-on by screw.
- Maximum round shaft φ16 and square shaft 12*12mm.
- Direction of rotation can be setting.
- Manual Override
- With 2 auxiliary switches are optional
- Power supply AC/DC 24V or AC 230V
Technical Datasheet of S6061-08~24 Standard Damper Actuator (Non Fail-Safe Damper Actuators)
| Item |
Unit位 |
S6061-08DN(F) |
S6061-16DN(F) |
S6061-24DN/(F) |
| Torque |
Nm |
8 |
16 |
24 |
| Damper area |
m2 |
2 |
4 |
6 |
| Running time |
sec |
30~40 |
72~88 |
117~143 |
| Power supply |
V |
24VAC/DC;220VAC;110VAC |
| Frequency |
Hz |
50/60Hz
7.5W 50/60Hz |
| Running consumption |
W |
3.9W(24V);4.8W(230V) |
| Maintaining consumption |
W |
0.4W(24V);1.2W(230V) |
| Weight |
Kg |
1.25 |
| Control signal |
2/3 point |
| Position signal |
2 auxiliary switches |
| Rotation angle |
0~90º(max 93°) |
| Limited angle |
5~85º(per step 5º) |
| Auxiliary switch rating |
3(1.5)Amp 250V |
| Life cycle |
>70000 cycles |
| Noise level |
45dB(A) |
| Electrical level |
Ⅱ |
| Protection level |
IP44 or IP54 |
| Ambient Temperature |
-20~+50℃ |
| Ambient Humidity |
5~95%RH |
| Storage temperature |
-40~+70℃ |
| Certification |
CE UL(Except 230V) |
Wiring Diagram of S6061-08~24 Standard Damper Actuator (Non Fail-Safe Damper Actuators)
The damper actuator can be controlled by 2 or 3 point.

Auxiliary Switch of S6061-08~24 Standard Damper Actuator (Non Fail-Safe Damper Actuators)
There are 2 auxiliary switches of the actuator, and you can set the angle 0-90° (the factory sets a is 10° and b is 80°). It will output a on/off signal when the actuator rotates the setting angle.

Control Signal and Choose the Direction of Rotation of S6061-08~24 Standard Damper Actuator (Non Fail-Safe Damper Actuators)
The direction of rotation changes according to the direction of pin.
Outline and Dimension of S6061-08~24 Standard Damper Actuator (Non Fail-Safe Damper Actuators)

What is HVAC Air Duct Damper Actuator?
The Function of HVAC Air Duct Damper Actuator
Product detail pictures:
Related Product Guide:
We are going to make every single effort for being excellent and excellent, and accelerate our ways for standing while in the rank of international top-grade and high-tech enterprises for
PriceList for Outside Air Damper Actuator -
S6061-08-16-24 Standard Damper Actuator (Non Fail-Safe Damper Actuators) – Soloon , The product will supply to all over the world, such as: Turkey
, Colombia
, Suriname
, Our factory insists on the principle of Quality First, Sustainable Development, and takes Honest Business, Mutual Benefits as our developable goal. All members sincerely thanks for all old and new customers' support. We will keep working hard and offering you the highest-quality products and service.Thanks.