Features of S6061-32A Damper Actuator Standard Damper Actuator (Non Fail-Safe Damper Actuators)
- Torque 32NM
- 0(4)…20mA 0(2)…10V
- Maximum round shaft φ20 and square shaft 16*16mm.
- Direction of rotation can be set.
- Manual Override
- With 2 auxiliary switches are optional
- Power supply AC/DC 24V or AC 230V
- Modulating
Outline and Dimension of S6061-32A Damper Actuator Standard Damper Actuator (Non Fail-Safe Damper Actuators)

Technical Datasheet of S6061-32A Damper Actuator Standard Damper Actuator (Non Fail-Safe Damper Actuators)
| Item |
Unit |
S6061-32AN(F) |
| Torque |
Nm |
32Nm |
| Damper area |
m2 |
6m2 |
| Running time |
sec |
114~138 |
| Power supply |
V |
24VAC/DC |
| Frequency |
Hz |
50/60
7.5W 50/60Hz |
| Running consumption |
W |
2.5W |
| Maintaining consumption |
W |
0.3W |
| Weight |
Kg |
1.25Kg |
| Control signal |
0(4)…20mA 0(2)…10V |
| Rotation angle |
0~90º(Max 93°) |
| Limited angle |
5~85º(Per step 5º) |
| Auxiliary switch rating |
3(1.5)Amp 250V |
| Life cycle |
>70000 cycles |
| Noise level |
45dB(A) |
| Electrical level |
Ⅱ |
| Protection level |
IP44 or IP54 |
| Ambient Temperature |
-20~+50℃ |
| Ambient Humidity |
5~95%RH |
| Storage temperature |
-40~+70℃ |
| Certificate |
CE UL |
Remark: After lead to the actuator wire through PG joint, the protection level can reach IP54.
Angle of Rotation Limiting of S6061-32A Damper Actuator Standard Damper Actuator (Non Fail-Safe Damper Actuators)
The rotation angle or working range of the actuator can be adjusted 5°by adapter so that can limit mechanically. You just press the locking clip to lose the adapter.

Wiring Diagram of S6061-32A Damper Actuator Standard Damper Actuator (Non Fail-Safe Damper Actuators)
0(4)…20mA and 0(2)…10V
The actuator’s main/subsidiary control:
Signal Control and Changing Direction of Rotation of S6061-32A Damper Actuator Standard Damper Actuator (Non Fail-Safe Damper Actuators)
The electronic controller of VR1 and VR2 can set the scope of control signals discretionally. VR1 is used for setting high-grade signals. And VR2 is used for setting low-grade signals. The leaving factory setting positions are matched with the control signal of 0…20mA, 0…10V.

Setting the Angle of Direction of S6061-32A Damper Actuator Standard Damper Actuator (Non Fail-Safe Damper Actuators)

Must make the contact pin(C) is as Same direction as motor plug.
Factory setting:
Switch a at 10° Switch b at 80° The switching position can be manually changed to any required position by turning the ratchet.
Auxiliary Switch of S6061-32A Damper Actuator Standard Damper Actuator (Non Fail-Safe Damper Actuators)
There are two auxiliary switches of S6061-32AF damper actuator, can set the angle 0-90° (factory sets 10° and 80°), it will show a signal when the actuator turns to the setting angle.

What is HVAC Air Duct Damper Actuator?
The Function of HVAC Air Duct Damper Actuator
Product detail pictures:
Related Product Guide:
We've been committed to offering easy,time-saving and money-saving one-stop purchasing support of consumer for
OEM China Actuator For Control Valve -
S6061-32A Damper Actuator Standard Damper Actuator (Non Fail-Safe Damper Actuators) – Soloon , The product will supply to all over the world, such as: Slovenia
, Swaziland
, Ukraine
, Strong infrastructure is the need of any organization. We are backed with a robust infrastructural facility that enables us to manufacture, store, quality check and dispatch our products worldwide. To maintain smooth work flow, we have sectioned our infrastructure into a number of departments. All these departments are functional with latest tools, modernized machines and equipment. Owing to which, we are able to accomplish voluminous production without compromising upon the quality.