Fitur S6025 Fluid Level Switch
Tegangan Rated VRated Arus A | Daya COS ø | 125VAC | 250 V AC |
Ora ana arus beban induksi | 1 | 15 | 15 |
Beban induksi | Arus beban penuh | 0.75 | 3.5 | 2.5 |
saiki | Saiki langsung | 0.45 | 21 | 15 |
Gambar 1: Parameter Teknologi 1
Ukuran katup | Konektor | MaxPressure (Mpa) | pangayoman | Diijini Suhu Sedheng. | Wetan.(Kg) | Modulating Range of Flow |
Ukuran Pipa | Min. | Maks. |
Ngurangi aliran | Tambah aliran | Ngurangi aliran | Tambah aliran |
3″ | 1″-11½ (NPT) | 1.60 | IP65 | -30~120 | 0.6 | 1″ | 2.5 | 4.2 | 8.5 | 8.8 |
2″ | 9.5 | 13.7 | 27 | 29 |
3″ | 19 | 27.5 | 50 | 53 |
Gambar 2: Parameter Teknologi 2
Nalika ana cairan sing cukup liwat pipa, daur ulang nutup antarane kontak abang lan biru.

Pemasangan S6022 Flow Switch
- Pasang ngalih ing bagean saka pipe ngendi ana roto terus saka ing paling limang diameteripun pipe ing saben sisih ngalih aliran.
- Ngalih kudu dipasang supaya terminal utawa kabel ndadékaké gampang diakses kanggo wiring.
- Screw saklar aliran menyang posisi supaya warata paddle ing amba tengen kanggo aliran.Panah ing sisih cilik kudu ngarah menyang arah aliran.
- Saklar kudu dipasang ing pipa horisontal utawa pipa vertikal kanthi aliran cairan munggah.Ora dianjurake kanggo instalasi ing ngendi aliran cairan mudhun.Nalika dipasang ing pipa vertikal kanthi aliran munggah, lelungan ngalih bakal mlaku kanthi aliran sing rada dhuwur tinimbang sing ditampilake ing Figure 4: "Tipe Aliran Khas", amarga efek gravitasi ing mekanisme switch.
- Kabeh sambungan kabel kudu digawe mung nggunakake konduktor tembaga.
- Kabeh kabel kudu dipasang sesuai karo Kode Listrik Nasional lan peraturan lokal
Flow Rate saka S6022 Aliran Ngalih
* + tokoh GPM kanggo ngalih karo 6 "paddle.
* Kanggo pipa baris 4 "lan 5", paddle 6" dipotong dadi dawane 4" lan 5".
* Kanggo tumindak ngalih, deleng gambar 3.
GPM (m3/jam) Dibutuhake kanggo Ngalih Ngalih |
Ukuran Pipa (in.) | 1 | 1-1/4 | 1-1/2 | 2 | 2-1/2 | 3 | 4* | 5* | 6* | 8* |
Imbuhan Minimal | Aliran mundhak → kuning ditutup** | 4.2(1.0) | 5.8(1.3) | 7.5(1.7) | 13.7(3.1) | 18.0(4.1) | 27.5(6.2) | 65.0(14.8) 37.0+ (8.4) | 125.0(28.4) 57.0+ (12.9) | 190.0(43.1) 74.0+ (16.8) | 375.0(85.2) 205.0+ (46.6) |
Arus mudhun → biru ditutup** | 2.5(0.6) | 3.7(0.8) | 5.0(1.1) | 9.5(2.2) | 12.5(2.8) | 19.0(4.3) | 50.0(11.4) 27.0+ (6.1) | 101.0(22.9) 41.0+ (9.3) | 158.0(35.9) 54.0+ (12.3) | 320.0(72.7) 170.0+ (38.6) |
Imbuhan maksimum | Aliran mundhak → kuning ditutup** | 8.8(2.0) | 13.3(3.0) | 19.2(4.4) | 29.0(6.6) | 34.5(7.8) | 53.0(12.0) | 128.0(29.1) 81.0+ (18.4) | 245.0(55.6) 118.0+ (26.8) | 375.0(85.2) 144.0 (32.7) | 760.0(172.6) 415.0+ (94.2) |
| Arus mudhun → biru ditutup** | 8.5(1.9) | 12.5(2.8) | 18.0(4.1) | 27.0(6.1) | 32.0(7.3) | 50.0(11.4) | 122.0(27.7) 76.0+ (17.3) | 235(53.4) 111.0+ (25.2) | 360.0(81.8) 135.0+ (30.7) | 730.0(165.8) 400.0+ (90.8) |