With our rich working experience and thoughtful companies, we have now been recognized as being a trustworthy supplier for a lot of global potential buyers for Wireless Hvac Sensors , 3 Point Actuator , Actuator For Control Valve , Presently, we are looking forward to even greater cooperation with overseas customers based on mutual benefits. Please feel free to contact us for more details.
High definition Air Flow Sensor For Hvac - S6011-RT/RTH Series of Temperature Transmitter & Temperature-Humidity Transmitter – Soloon Detail:

Operation voltage DC 24V
Output signal 0~10V or 4-20mA
Measuring range Temperature 0~50℃
Humidity 0~100%RH
Measuring Accuracy Temperature ±1℃ or ±0.5℃
RH ±5%RH or ±3%
Ambient temperature -20℃~60℃
Storage -40℃~70℃, non-condensing
Housing ABS

Dimensions of S6011-RT/RTH Series of Temperature Transmitter & Temperature-humidity Transmitter

s6011-rt-rth-series-of-temperature-transmitter-temperature-humidity-transmitter-2

S6011-RT Wiring diagram of S6011-RT/RTH Series of Temperature Transmitter & Temperature-humidity Transmitter

s6011-rt-rth-series-of-temperature-transmitter-temperature-humidity-transmitter-3

S6011-RTH Wiring diagram of S6011-RT/RTH Series of Temperature Transmitter & Temperature-humidity Transmitter

s6011-rt-rth-series-of-temperature-transmitter-temperature-humidity-transmitter-4

Mounting of S6011-RT/RTH Series of Temperature Transmitter & Temperature-humidity Transmitter

  • The transmitters are suitable for direct wall mounting or ceiling mounting using four screw holes on the base. The wiring must be inserted from the back. For mounting:
  • Choose an appropriate location to achieve good control of the ambient temperature. The room transmitters only sense the temperature or humidity at the location where it is mounted.
  • The transmitters should not be mounted close to windows or doors in order to avoid draught. On the other hand, sufficient air circulation must be ensured in order to sense the actual temperature of the room.
  • Place insulation material in the wiring conduit in order to prevent the introduction of air from outside the room.
  • The transmitter should not be exposed to direct radiation or to the sun as this could lead to inaccurate measurement.

Product detail pictures:

High definition Air Flow Sensor For Hvac -
 S6011-RT/RTH Series of Temperature Transmitter & Temperature-Humidity Transmitter   – Soloon detail pictures


Related Product Guide:

We're going to dedicate ourselves to offering our esteemed shoppers with the most enthusiastically considerate solutions for High definition Air Flow Sensor For Hvac - S6011-RT/RTH Series of Temperature Transmitter & Temperature-Humidity Transmitter – Soloon , The product will supply to all over the world, such as: Israel , Algeria , Bolivia , Now, with the development of internet, and the trend of internationalization, we've got decided to extend business to overseas market. With the propose of bringing more profits to oversea customers by providing directly abroad. So we have changed our mind, from home to abroad, hope to give our customers more profit, and looking forward to more chance to make business.
Contact Us Product Inquiry
Contact Us
If you are interested in our products.
Please fill in the form & Contact Us.
+86 10 67863711