S6061-08/16 Modulating Rapid Running Damper Actuator – Soloon Detail:
Features of S6061-08/16 Modulating Rapid Running Damper Actuator
- With 2 auxiliary switches are optional
- Torque 08/16NM
- Power supply AC/DC 24V or AC 230V
- Modulating
Outline and Mounting Dimension of S6061-08/16 Modulating Rapid Running Damper Actuator

Technical Datasheet of S6061-08/16 Modulating Rapid Running Damper Actuator
| Item |
Unit |
S6061-08
AFK |
S6061-16
AFK |
S6061-08ANK |
S6061-16ANK |
| Torque |
Nm |
8 |
16 |
8 |
16 |
| Damper area |
m2 |
2 |
4 |
2 |
4 |
| Running time |
sec |
8 |
16 |
8 |
16 |
| Power supply |
V |
24VAC/DV |
| Frequency |
Hz |
50/60
7.5W 50/60Hz |
| Running consumption |
W |
8.5W |
| Maintaining consumption |
W |
0.7W |
| Weight |
Kg |
1.Kg |
| Control signal |
0(4)…20mA 0(2)…10V |
| Rotation angle |
0~90º(Max 93°) |
| Limited angle |
5~85º(Per step 5º) |
| Auxiliary switch rating |
3(1.5)Amp 250V |
| Life cycle |
>70000 cycles |
| Noise level |
45dB(A) |
| Electrical level |
Ⅱ |
| Protection level |
IP44 or IP54 |
| Ambient Temperature |
-20~+50℃ |
| Ambient Humidity |
5~95%RH |
| Storage temperature |
-40~+70℃ |
|
| Certificate |
CE UL(Except 230V) |
Remark: After lead out the Actuator wire by PG joint, the IP Protection can reach IP54.
Angle of Rotation Limiting of S6061-08/16 Modulating Rapid Running Damper Actuator
The rotation angle or working range of the actuator can be adjusted 5°by adapter so that can limit mechanically. You just press the locking clip to lose the adapter.
Wiring diagram of S6061-08/16 Modulating Rapid Running Damper Actuator
S6061-08/16AK Damper Actuator can operate by 0(4)…20mA and 0(2)…10V
Main/subsidiary control of S6061-08/16 Modulating Rapid Running Damper Actuator

Control Signal and Choose the Rotate direction of S6061-08/16 Modulating Rapid Running Damper Actuator

The electronic controller of VR1 and VR2 can set the scope of control signals discretionally. VR1 is used for setting high-grade signals. And VR2 is used for setting low-grade signals. The leaving factory setting positions are matched with the control signal of 0…20mA, 0…10V.
Setting the angle of direction of S6061-08/16 Modulating Rapid Running Damper Actuator
Must make the contact pin(C) is as Same direction as motor plug.
Factory setting of S6061-08/16 Modulating Rapid Running Damper Actuator

Switch at 10° – Switch b at 80°
The switching position can be manually changed to any required position by turning the ratchet.
Auxiliary Switch specification of S6061-08/16 Modulating Rapid Running Damper Actuator
There are two auxiliary switches of S6061-08/16AFK damper actuator, can set the angle 0-90° (factory sets 10° and 80°), it will show a signal when the actuator turns to the setting angle.
What is HVAC Air Duct Damper Actuator?
The Function of HVAC Air Duct Damper Actuator
Product detail pictures:
Related Product Guide:
We believe that long expression partnership is often a result of top of the range, value added service, prosperous encounter and personal contact for
Free sample for At Controls Actuator -
S6061-08/16 Modulating Rapid Running Damper Actuator – Soloon , The product will supply to all over the world, such as: Austria
, South Africa
, Turkey
, We set a strict quality control system. We have return and exchange policy, and you can exchange within 7 days after receive the wigs if it is in new station and we service repairing free for our products. Please feel free to contact us for further information if you have any questions. We are glad to work for every client.