ExS6061SF-05/10/15 Explosion-proof Actuator – Soloon Detail:
Specification of ExS6061SF-05/10/15DF/24(230)V
| Model
Para. |
ExS6061SF-05DF/24V |
ExS6061SF-05DF/230V |
ExS6061SF-10DF/24V |
ExS6061SF-10DF/230V |
ExS6061SF-15DF/24V |
ExS6061SF-15DF/
230V |
| Torque |
5Nm |
10Nm |
15Nm |
| Damper Size |
1m2 |
3m2 |
4.5m2 |
| Power Supply |
AC220V AC24V DC24V 50/60Hz i ≤0.2A
AC220V 50/60Hz |
| Consumption |
7W run/3W remain |
10W run/3W remain |
12W run/3W remain |
| Wire Size |
10VA |
| Connection cable |
Power:1m cable 3*0.5 m2 |
| Auxiliary Switch (F):1m cable 6*0.5 m2 |
| Running Time |
Motor≤150s;Spring Return≤30s |
| Angle of Rotation |
Max 93º |
| Position Indication |
Mechanical indicator |
| Weight |
5Kg |
| Life Cycle |
≥10000 cycles |
| Sound Level |
50dB(A)and62dB(A) |
| Protection Level |
Ⅲ(safety low voltage) |
Ⅱ(full insulation) |
| IP Protection |
IP66 |
| Ambient Temperature |
-20~+60℃ |
| Ambient Humidity |
5~95%RH |
| Explosion-proof Mark |
Ex db ⅡB T6 Gb
Ex tb IIIC T85°C Db |
Features of ExS6061SF-05/10/15 Explosion-proof Actuator
- Single control
- Form-fit 12x12cm shaft
- Universal shift plug
- Two auxiliary switches
- Cast aluminum housing, compacting type
- Safety meets IP66
Compliances of ExS6061SF-05/10/15 Explosion-proof Actuator
- IEC60079-0:2017, EN60079-0:2012+A11:2013 electrical apparatus in explosive gas atmosphere – part0: General requirements.
- IEC60079-1:2014 ;EN60079-1:2007 electrical apparatus in explosive gas atmosphere – part1:flameproof“d”.
- IEC60079-31:2013,EN60079-31:2014 explosive atmospheres part31: Equipment dust ignition protection by enclosure “t”. Usage and maintenance
- Cable connector and the housing mating thread size M16 × 1.5, cable diameter size Φ6-Φ8. When the equipment is used on-site, the cable gland should be installed by the user, whose protection grade should not be lower than Ⅱ2D Ex tb IIIC T85°C Db.
- Within ground terminal tightening torque 2N.m.
- Flameproof joint tightening torque is 3.2N.m.
- External ground bolt M4X6, pressing 4mm² conductors.
- Disassembly is prohibited without permission Do not open with power. please do not open the cover in the explosive gas. Need to use a damp cloth when opening.l
- Repair of the flanged joints must be made in compliance with the structural specifications provided by the manufacturer. Repairs must not be made on the basis of values specified in table 3 and table 4 of EN 60079-1:2007.
- The entry shall be equipped with Ex certified cable glands with a compatible mode of protection for the intended use.
- When assembly, operation and maintenance, the operator should follow the requirements of EN 60079-14, besides the instruction manual.
- Repair and overhaul shall comply with EN 60079-19.
Electrical Connection and Outline of ExS6061SF-05/10/15 Explosion-proof Actuator

What is HVAC Air Duct Damper Actuator?
The Function of HVAC Air Duct Damper Actuator
Product detail pictures:
Related Product Guide:
continue to enhance, to be certain solution top quality in line with market and buyer standard requirements. Our corporation has a excellent assurance program are actually established for
Free sample for At Controls Actuator -
ExS6061SF-05/10/15 Explosion-proof Actuator – Soloon , The product will supply to all over the world, such as: Angola
, Moldova
, Paraguay
, We now have been making our goods for more than 20 years . Mainly do wholesale , so we've the most competitive price , but highest quality. For the past years , we got very good feedbacks , not only because we offer good solutions , but also because of our good after-sale service . We are here waiting for yourself for your inquiry.