We aim to find out high quality disfigurement in the generation and provide the most effective services to domestic and abroad clients wholeheartedly for
Hvac Float Switch Cost
,
Hvac Air Flow Meter
,
Electrically Operated Control Valve
, We believe this sets us apart from the competition and makes customers choose and trust us. We all wish to create win-win deals with our customers, so give us a call today and make a new friend!
Factory Outlets Actuator Valve For Fcu -
S6061SC-10(15) Nm (15Nm 100-240V) Spring Return Damper Actuator (Fail-Safe Damper Actuators) – Soloon Detail:
Features of S6061SC-10(15) Nm (15Nm 100-240V) Spring Return Damper Actuator (Fail-Safe Damper Actuators)
- ON/OFF or 0-10V
- Shaft size: Max.φ18mm.
- Direction of rotation can be setting.
- Two Optional Auxiliary Switches
- IP 54 standard.
- Without Manuel Override
Technical Datasheet of S6061SC-10(15) Nm (15Nm 100-240V) Spring Return Damper Actuator (Fail-Safe Damper Actuators)
| Item |
S6061SC-10DN(F) |
S6061SC-10DN(F) |
S6061SC-10AN(F) |
S6061SC-15DN(F) |
S6061SC-15DN(F) |
S6061SC-15AN(F) |
| Torque |
10Nm |
15Nm |
| Damper area |
2m2 |
3m2 |
| Power supply |
24VAC/DC, 230VAC 50/60Hz |
AC100-240V |
24VAC |
| Operating Power Consumption |
5W |
6W |
| At end stops Power Consumption |
2.5W |
2.5W |
| Wire size |
10VA |
7VA |
10VA |
7VA |
| Connection cable |
D type power:1m cable 2*0.75m2 A type power:1m cable 4*0.5 m2 |
| Auxiliary switch (F):1m cable 6*0.5 m2 |
| Control signal |
On/off |
0~10V |
On/off |
0~10V |
| Running time |
Motor≤100S;Spring return≤20S |
Motor≤130S;spring return≤20S |
| Rotation angle |
0~90°(Max 93º) |
| Limited angle |
5~85º(Per step5º) |
| Indicate |
Mechanical indicator |
| Weight |
2.4Kg |
| Life cycle |
70000 |
| Noise level |
50dB(A) and 62dB(A) |
| Electric level |
Ⅲ |
Ⅱ |
Ⅲ |
Ⅲ |
Ⅱ |
Ⅲ |
| IP protection |
IP54 |
| Ambient Temperature |
-20~+50℃ |
| Ambient Humidity |
5~95%RH |
| Certificate |
CE & UL |
Wiring Diagram of S6061SC-10(15) Nm (15Nm 100-240V) Spring Return Damper Actuator (Fail-Safe Damper Actuators)
Modulating damper actuator can be controlled by 0-10V

Auxiliary Switch of S6061SC-10(15) Nm (15Nm 100-240V) Spring Return Damper Actuator (Fail-Safe Damper Actuators)

![s6061sc-10-15-nm-15nm-100-240v-spring-return-damper-actuator-fail-safe-damper-actuators-3]](//cdn.goodao.net/soloonactuators/s6061sc-10-15-nm-15nm-100-240v-spring-return-damper-actuator-fail-safe-damper-actuators-3.jpg)
What is HVAC Air Duct Damper Actuator?
The Function of HVAC Air Duct Damper Actuator
Product detail pictures:
Related Product Guide:
We also offer product sourcing and flight consolidation services. We have our own factory and sourcing office. We can provide you with almost every type of product related to our product range for
Factory Outlets Actuator Valve For Fcu -
S6061SC-10(15) Nm (15Nm 100-240V) Spring Return Damper Actuator (Fail-Safe Damper Actuators) – Soloon , The product will supply to all over the world, such as: Nigeria
, Colombia