We continuously execute our spirit of Innovation bringing development, Highly-quality ensuring subsistence, Management advertising and marketing gain, Credit history attracting buyers for Air Operated Valve Actuators , Co2 Detector Hvac , Steam Actuator Valve , Any needs from you'll be paid out with our best notice!
Chinese wholesale Temperature Sensor For Hvac System - S6011-RT/RTH Series of Temperature Transmitter & Temperature-Humidity Transmitter – Soloon Detail:

Operation voltage DC 24V
Output signal 0~10V or 4-20mA
Measuring range Temperature 0~50℃
Humidity 0~100%RH
Measuring Accuracy Temperature ±1℃ or ±0.5℃
RH ±5%RH or ±3%
Ambient temperature -20℃~60℃
Storage -40℃~70℃, non-condensing
Housing ABS

Dimensions of S6011-RT/RTH Series of Temperature Transmitter & Temperature-humidity Transmitter

s6011-rt-rth-series-of-temperature-transmitter-temperature-humidity-transmitter-2

S6011-RT Wiring diagram of S6011-RT/RTH Series of Temperature Transmitter & Temperature-humidity Transmitter

s6011-rt-rth-series-of-temperature-transmitter-temperature-humidity-transmitter-3

S6011-RTH Wiring diagram of S6011-RT/RTH Series of Temperature Transmitter & Temperature-humidity Transmitter

s6011-rt-rth-series-of-temperature-transmitter-temperature-humidity-transmitter-4

Mounting of S6011-RT/RTH Series of Temperature Transmitter & Temperature-humidity Transmitter

  • The transmitters are suitable for direct wall mounting or ceiling mounting using four screw holes on the base. The wiring must be inserted from the back. For mounting:
  • Choose an appropriate location to achieve good control of the ambient temperature. The room transmitters only sense the temperature or humidity at the location where it is mounted.
  • The transmitters should not be mounted close to windows or doors in order to avoid draught. On the other hand, sufficient air circulation must be ensured in order to sense the actual temperature of the room.
  • Place insulation material in the wiring conduit in order to prevent the introduction of air from outside the room.
  • The transmitter should not be exposed to direct radiation or to the sun as this could lead to inaccurate measurement.

Product detail pictures:

Chinese wholesale Temperature Sensor For Hvac System -
 S6011-RT/RTH Series of Temperature Transmitter & Temperature-Humidity Transmitter   – Soloon detail pictures


Related Product Guide:

Fast and good quotations, informed advisers to help you choose the correct product that suits all your needs, a short production time, responsible quality control and different services for paying and shipping affairs for Chinese wholesale Temperature Sensor For Hvac System - S6011-RT/RTH Series of Temperature Transmitter & Temperature-Humidity Transmitter – Soloon , The product will supply to all over the world, such as: Nicaragua , Austria , Toronto , Thus far, our item associated with printer dtg a4 may be shown in most foreign nations as well as urban centers, which are sought after simply by targeted traffic. We all highly imagine that now we have now the full capacity to present you with contented merchandise. Desire to collect requests of your stuff and produce the long-term co-operation partnership. We very seriously promise:Csame top quality, better price; exact same selling price, higher quality.
Contact Us Product Inquiry
Contact Us
If you are interested in our products.
Please fill in the form & Contact Us.
+86 10 67863711