S6062A Electric Control Valve

S6062A Electric Control Valve

S6062A series Electric Control Valve assemble with 1200N and 5000N force actuator and valve size from DN40 to DN200, with widely used in air conditioning, refrigeration, heating and building automation system, can adjust the medium flow precision, achieved goal to control temperature, humidity, pressure and energy saving.


Features & Benefits



Features and Benefits

Quality components

Die-casting aluminum bracket and actuator cover steel gears, to keep the valve acting stable and safety.

AC synchronous motor, built-in two floating auxiliary switch, equip with shut power function while in position to protect motor.

High control precision, quick response speed, low power consumption, low noise. Configuration travel self-adaption, easy to install and test.

High quality AC synchronous motor, long life usage

Built-in two floating auxiliary switch, shut power function while in position to protect motor. High control precision, quick response speed, low power consumption, low noise.

With Manual Lever easy to operate valve while power off

More choices

On-Off, floating or modulating 2way and 3way

DN40 to DN300


Technical Data & Dimensions


Actuator

Type

Actuator For DN40-DN65

Actuator For DN80-DN100


S6062A-DV12

S6062A-FV12

S6062A-MV12

S6062A-DV25

S6062A-FV25

S6062A-MV25

Action Control

On/Off

Floating

Modulating

On/Off

Floating

Modulating

Voltage

AC220V

50/60Hz

AC24V

50/60Hz

AC24V 50/60Hz

AC220V

50/60Hz

AC24V

50/60Hz

AC24V 50/60Hz

Motor

AC Synchronous Motor

AC Synchronous Motor

Force

1200N

2500N

Control Signal

On/Off

3-point

0-10VDC or

4-20mADC

On/Off

3-point

0-10VDC or

4-20mADC

Power

6.5VA

16VA

Max. Stroke

22mm

44mm

Working Temp.

-5—55℃

-5—55℃

IP Class

IP44

IP44


Type

Actuator For DN125-DN150

Actuator For DN200-DN300


S6062A-DV40

S6062A-FV40

S6062A-MV40

S6062A-DV50

S6062A-FV50

S6062A-MV50

Action Control

On/Off

Floating

Modulating

On/Off

Floating

Modulating

Voltage

AC220V

50/60Hz

AC24V

50/60Hz

AC24V 50/60Hz

AC220V

50/60Hz

AC24V

50/60Hz

AC24V 50/60Hz

Motor

AC Synchronous Motor

AC Synchronous Motor

Force

4000N

5000N

Control Signal

On/Off

3-point

0-10VDC or

4-20mADC

On/Off

3-point

0-10VDC or

4-20mADC

Power

6.5VA

16VA

Max. Stroke

44mm

44mm

Working Temp.

-5—55℃

-5—55℃

IP Class

IP44

IP44


Valve Body

Size

DN40

DN50

DN65

DN80

DN100

DN125

DN150

DN200

DN250

Stem Stroke(mm)

20

20

20

40

40

40

40

40

40

Close-off

Pressure( MPa)

0.5

0.4

0.3

0.5

0.4

0.3

0.3

0.3

0.3

Kvs

20

35

52

88

140

210

320

520

530

L

180

190

200

250

275

350

400

480

630

H

490

500

510

523

538

548

564

603

H1

2 way

75

84

92

100

110

125

142

170

3 way

108

119

127

135

147

162

181

209

Flange

4-M16

4-M16

4-M16

8-M16

8-M16

8-M16

8-M20

12-M20

10-M20

Nominal Pressure

1.6MPa

Fluid Temperature

Water 2℃-90℃

Service Medium

Chilled/Hot Water


Material

Body

Ductile Iron

Bore

304SS

Stem

304SS

Sealing

PTFE, V sealing, Spring self-compensate

Leakage

Less than 0.5% of Kv.

1200N_Actuator.png

1200N Actuator

5000N_Actuator.png

5000N Actuator

Manual Operation:

1. Insert handle

2. Rotate according “UP” and “DOWN” indicate.


Wiring

Wiring.png

Commissioning Process

Commissioning_Process.png

1. Press K1 button about 5s, waiting LED1 lighted for 5s.

2. Release the K1 button and then press once again.

3. The actuator will act for a full stroke.

4. When act finished, commissioning complete.

5. Set input signal


DIP Switch can adjust the input signal and motor rotate direction.

Installations


1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition.

2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application.

3. Installer must be a trained, experienced service technician.

4. The valve should be installed somewhere easy to install and maintain.

5. Horizontal installation, that means the motor should be in the above of valve body to avoid humidity.

6. 2 way and 3 way connection as flowing.


Install Actuator


The Manufacturer of HVAC Control Valves and Valve Actuators The Manufacturer of HVAC Control Valves and Valve Actuators
The HVAC Actuator Valve Working Principle The HVAC Actuator Valve Working Principle
HVAC Control Valves and Actuators HVAC Control Valves and Actuators
Contact Us Product Inquiry
Contact Us
If you are interested in our products.
Please fill in the form & Contact Us.
+86-10-67886688